Mitsubishi Electric IQSS-R-E Reference Manual page 97

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

■Devices used in the program
Device
M0
M1000
M1100
M1200
M1300
M2000
M3000
M3500
M3550
D1000
*1
D2000.1
*1
D2000.3
*1
D2000.4
*1
D2001.0
*1
D2001.1
*1
D2001.2
*1
D2001.4
*1
D2013.B
D5000
D5001
D5002
D5003
SM1435
SM1439
SM1442
SD1435
SD1436
SD1437
SD1438
SD1439
SD1440
SD1441
SD1444
SD1446
SD1448
SD1449
SD1452
SD1453
SW80.0
SW160.0
X10
X11
X1F
*1 A device used when the remote input (RX) is set to D2000.
For details on special relays (SM) and special registers (SD) to be used and their setting ranges, refer to the
following section.
Page 355 Special Relay (SM)/Special Register (SD) List
Description
Initialization trigger
Restoration execution trigger
Restoration right-to-use request trigger
Restoration right-to-use confirmation trigger
Restoration setting/start trigger
Restoration execution cancellation trigger
Restoration execution normal completion display
Restoration execution abnormal completion display
Restoration right-to-use acquisition failure
Right-to-use number storage area
DP/DN short error
Transmission cable voltage drop error
DP/DN disconnection error
Slave module alarm signal
Parameter access completion flag
Parameter access error
Automatic address detection flag
Remote READY
Restoration number of normally completed devices
Restoration number of devices completed with an error
Restoration error cause in a module
Restoration error cause in a device
Restoration execution enabled
Restoration request
Restoration cancellation request
Restoration use request
Restoration right-to-use acquisition status
Restoration target module/execution unit setting
Restoration folder number setting
Restoration target setting (target module)
Restoration target setting (target device 1)
Restoration target setting (target device 2)
Operation setting when a data restoration error occurs
Restoration execution status
Restoration number of normally completed devices
Restoration number of devices completed with an error
Restoration error cause in a module
Restoration error cause in a device
Station No.1 data link status
Station No.1 remote register use prohibited status
Module error
Host station data link status
Module READY
4.5 Backing up/Restoring Data of Devices Supporting iQSS
Value
10A0H
Lower 8 bits: 2H
Upper 8 bits: 3H
18
1H
1
517
1H
4 CC-Link
4
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

13jv28