Mitsubishi Electric IQSS-R-E Reference Manual page 346

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

Panasonic Industrial Devices SUNX Co., Ltd.
Type/model name
■Communication unit for CC-Link
• SC-GU3-01
■Analog input unit
• SC-T1JA
• SC-A01
• SC-A02
■Digital fiber sensor
• FX-301
• FX-305
• FX-501
• FX-502
■Digital laser sensor
• LS-403
■Head-separated dual display
digital pressure sensor
• DPS-401
• DPS-402
APPX
344
Appendix 4 Considerations for Using Device Supporting iQSS
Function
• Sensor parameter read/write
• Sensor/device monitor
Data backup/restoration
Sensor/device monitor
Sensor/device monitor
Data backup/restoration
Sensor/device monitor
Data backup/restoration
Sensor/device monitor
Data backup/restoration
Consideration
Communication unit for CC-Link is required to be interconnected with
respective sensor amplifiers supporting optical communication, and to which
an end unit (SC-GU3-EU) is attached at the end.
Neither the sensor parameter read/write function nor the sensor/device
monitor function can be performed on the station without an end unit.
Communication unit for CC-Link is required to be interconnected with
respective sensor amplifiers supporting optical communication, to which an
end unit (SC-GU3-EU) is attached at the end.
The station to which no end unit is attached, the data may not be backed up
properly.
When one communication unit for CC-Link is connected to the CC-Link
master/local module, the error code 4805H is stored to SD1452 during the
data backup process.
When two or more communication unit for CC-Link are connected to CC-Link
master/local module, and if a station without an end unit is included, data
backup is performed only on the station with an end unit, not on the station
without an end unit.
Note that error code is not stored.
When performing the Sensor/Device Monitor function, connecting an analog
voltage output signal of other device to an analog voltage input terminal is
required.
If no signal is connected, '0' is obtained as a current value.
When performing the sensor/device monitor function, connecting a fiber
head to a digital fiber sensor is required.
Data can be obtained even if a fiber head is not connected, but a detected
value differs from a value detected when a fiber head is connected.
When data backup/restoration failed, an error code is stored to SD1453.
Check the error code and take corrective actions. (Page 347 Error Code
List, or  User's manual for data backup/restoration target modules)
When performing the sensor/device monitor function, connecting a laser
sensor head to a digital laser sensor is required.
Data can be obtained even if a laser sensor head is not connected, but a
detected value differs from a value detected when a laser sensor head is
connected.
When data backup/restoration failed, an error code is stored to SD1453.
Check the error code and take corrective actions. (Page 347 Error Code
List, or  User's manual for data backup/restoration target modules)
When performing the sensor/device monitor function, connecting a pressure
sensor head to a head-separated dual display digital pressure sensor is
required.
When a pressure sensor head is not connected, '0' is acquired for a detected
value and 'Er42' is displayed on a sensor amplifier.
When data backup/restoration failed, an error code is stored to SD1453.
Check the error code and take corrective actions. (Page 347 Error Code
List, or  User's manual for data backup/restoration target modules)