■Setting the restoration setting
1.
Setting a target module type
Set a target module with the lower 8 bits of SD1362 (iQ Sensor Solution data backup/restoration target module, execution unit
setting).
Target module type
3H: Ethernet
2.
Setting an execution unit
Set a unit to specify the range of data to be restored at once.
Specify the execution unit to the upper 8 bits of SD1362.
Execution unit
1H: Module unit
2H: IP address unit
3.
Selecting a folder for data restoration
Set a folder number to SD1363 (iQ Sensor Solution backup/restoration folder number setting).
Target folder
0 to 99: Target folder specification
4.
Setting a target device
• Setting a module
When '1H' (module unit) is set for the execution unit, set a module to SD1364 (iQ Sensor Solution data backup/restoration
target setting (target module)).
Target device (Module)
03FFH: Built-in Ethernet
• Setting IP addresses
When '2H' (IP address unit) is set for the execution unit, set target devices (IP address) to SD1365 (iQ Sensor Solution data
backup/restoration target setting (target device 1)) and SD1366 (iQ Sensor Solution data backup/restoration target setting
(target device 2)).
Number
Target device (IP address)
SD1365
0 to 65536 (FFFFH): IP address (lower 16 bits)
SD1366
0 to 57343 (DFFFH): IP address (upper 16 bits)
*1 IP addresses within the range from 0.0.0.1 to 223.255.255.254
5.
Setting the operation setting when a data restoration error occurs
Set the operation to be performed when the data restoration fails on some devices while being processed to multiple devices
supporting iQSS to the lower 8 bits of SD1367 (iQ Sensor Solution data backup/restoration operation setting).
Operation on error
0H: Continue
1H: Stop
Description
Set this to specify a device supporting iQSS which is connected to Ethernet.
Description
Set this to collect the information of the device supporting iQSS connected to an Ethernet and to perform data
restoration.
Devices supporting iQSS which communicate with a restoration target module are restored.
Set this to specify the device supporting iQSS with the specified IP address among the devices supporting iQSS
which are connected to Ethernet.
Description
Specify a number (0 to 99) of the backup folder name to be restored.
Description
Set this to specify a device supporting iQSS which is connected to a built-in Ethernet.
Description
*1
Set the IP address of a target device supporting iQSS.
*1
Description
Set this to continue a data restoration even if it fails on some devices.
Set this to stop a data restoration if it fails on some devices.
10.5 Backing up/Restoring Data of Devices Supporting iQSS