■Setting the backup setting
1.
Setting a target module type
Set a target module with the lower 8 bits of SD1362 (iQ Sensor Solution data backup/restoration target module, execution unit
setting).
Target module type
3H: Ethernet
2.
Setting an execution unit
Set a unit to specify the range of data to be backed up at once.
Specify the execution unit to the upper 8 bits of SD1362.
Execution unit
1H: Module unit
2H: IP address unit
3.
Setting a number for a data backup folder name
Set a folder number to SD1363 (iQ Sensor Solution backup/restoration folder number setting).
Target folder
FFFFH: Automatic specification (default)
FFFEH: Automatic specification (folder
deletion supported)
0 to 99: Target folder specification
*1 When the specified folder number exists, the operation to be performed depends on the specification of the execution unit as follows:
Execution unit
1H: Module unit
2H: IP address unit
4.
Setting a target device
• Setting a module
When '1H' (module unit) is set for the execution unit, set a module to SD1364 (iQ Sensor Solution data backup/restoration
target setting (target module)).
Target device (Module)
03FFH: Built-in Ethernet
• Setting IP addresses
When '2H' (IP address unit) is set for the execution unit, set target devices (IP address) to SD1365 (iQ Sensor Solution data
backup/restoration target setting (target device 1)) and SD1366 (iQ Sensor Solution data backup/restoration target setting
(target device 2)).
Number
Target device (IP address)
SD1365
0 to 65536 (FFFFH): IP address (lower 16 bits)
SD1366
0 to 57343 (DFFFH): IP address (upper 16 bits)
*1 IP addresses within the range from 0.0.0.1 to 223.255.255.254
10 Ethernet
292
10.5 Backing up/Restoring Data of Devices Supporting iQSS
Description
Set this to specify a device supporting iQSS which is connected to Ethernet.
Description
Set this to collect the information of the device supporting iQSS connected to an Ethernet and to perform data
backup.
Device supporting iQSS which communicate with a backup target module are backed up.
Set this to specify the device supporting iQSS with the specified IP address among the devices supporting iQSS
which are connected to Ethernet.
Description
Among the numbers (0 to 99) that are not used for backup folder names, the smallest number is used for a new
backup folder name.
An error occurs when unused number is no longer available due to such cases as the number of folders reached
the upper limit.
Among the numbers (0 to 99) that are not used for backup folder names, the smallest number is used for a new
backup folder name.
The oldest backup folder (date_number) is deleted and the number of the deleted folder is used for a new backup
folder name when unused number is no longer available due to such cases as the number of folders reached the
upper limit.
Specify a number (0 to 99) of the backup folder name.
When another folder with the same number exists, the target data is overwritten in execution unit without
*1
changing the folder name.
Operation
When the backup data with the same target module exists, the backup folder (target module_IP address) is
deleted before performing data backup.
When the backup data with the same target module and the same target IP address exists, the backup folder
(target module_IP address) is deleted before performing data backup.
Description
Set this to specify a device supporting iQSS which is connected to a built-in Ethernet.
Description
*1
Set the IP address of a target device supporting iQSS.
*1