CC-Link IE Field Network

Error code
Error and cause
BAD1H
Data restoration was performed
using backup data of module
that is different from module for
data restoration target.
BAD2H
Data restoration was performed
using backup data of newer
module than module for data
restoration target.
BAD3H
Corrupted backup data was
restored.
BAD4H
Data backup was performed in
the state of being unable to
create backup data of module.
BAD5H
An attempt was made to restore
data to a remote I/O module
when the automatic I/O
parameter setting is enabled.
*1 The error code '4807H' is stored to SD1452 if data is backed up and restored with any of the following combinations of modules.
⋅Data backup for NZ2GF2B1N1-16D, and data restoration for NZ2GF2B1-16D or NZ2GF2B1N-16D
⋅Data backup for NZ2GF2B1N1-16T, and data restoration for NZ2GF2B1-16T or NZ2GF2B1N-16T
⋅Data backup for NZ2GF2B1N1-16TE, and data restoration for NZ2GF2B1-16TE or NZ2GF2B1N-16TE
APPX
350
Appendix 5 Error Code List
Corrective action
Use the data that was backed up by using a module with the
same model name as one used for data restoration.
Perform the data restoration function by using the data that was
backed up from a module with the same version or earlier than
one used for data restoration.
Use another backup data and retry.
Non-volatile memory data (parameter) error occurred. Retry data
backup after removing the error.
Data cannot be restored to a remote I/O module when the
automatic I/O parameter setting is enabled.
Disable the automatic I/O parameter setting for the restoration
target remote I/O module.
Type/model name
■Basic Digital Input Module
• NZ2GF2B1-16D, NZ2GF2B1N-
*1
16D, NZ2GF2B1N1-16D
,
NZ2GF2B2-16A, NZ2GF2B1-
32D
• NZ2GFCE3-16D, NZ2GFCE3-
16DE, NZ2GFCE3N-32D
• NZ2GFCM1-16D, NZ2GFCM1-
16DE
• NZ2GFCF1-32D
• NZ2GF2S2-16A
■Basic Digital Output Module
• NZ2GF2B1-16T, NZ2GF2B1-
16TE, NZ2GF2B1N-16T,
NZ2GF2B1N-16TE,
*1
NZ2GF2B1N1-16T
,
*1
NZ2GF2B1N1-16TE
,
NZ2GF2B2-16R, NZ2GF2B2-
16S, NZ2GF2B1-32T,
NZ2GF2B1-32TE
• NZ2GFCE3-16T, NZ2GFCE3-
16TE, NZ2GFCE3N-32T
• NZ2GFCM1-16T, NZ2GFCM1-
16TE
• NZ2GFCF1-32T
• NZ2GF2S2-16R, NZ2GF2S2-
16S
■Basic Digital I/O Combined
Module
• NZ2GF2B1-32DT, NZ2GF2B1-
32DTE
• NZ2GFCE3N-32DT
• NZ2GFCF1-32DT
■Basic Analog Input Module
• NZ2GF2BN-60AD4
■Basic Analog Output Module
• NZ2GF2BN-60DA4
■High-Speed Counter Module
• NZ2GFCF-D62PD2
■Basic Digital Input Module
• NZ2GF2B1N1-16D, NZ2GFCF1-
32D
■Basic Digital Output Module
• NZ2GF2B1N1-16T,
NZ2GF2B1N1-16TE,
NZ2GFCF1-32T
■Basic Digital I/O Combined
Module
• NZ2GFCF1-32DT

Advertisement