logging sendmail level

To open a connection, the switch first selects the server that successfully sent
mail during the last connection, or the first server configured by this command.
If it fails to send mail, the switch selects the next server in the list and tries to
send mail again. If it still fails, the system will repeat the process at a periodic
interval. (A trap will be triggered if the switch cannot successfully open a
connection.)
Example
Console(config)#logging sendmail host 192.168.1.19
Console(config)#
This command sets the severity threshold used to trigger alert messages. Use the
no form to restore the default setting.
Syntax
logging sendmail level level
no logging sendmail level
level - One of the system message levels
the selected level down to level 0. (Range: 0-7; Default: 7)
Default Setting
Level 7
Command Mode
Global Configuration
Command Usage
The specified level indicates an event threshold. All events at this level or higher will
be sent to the configured email recipients. (For example, using Level 7 will report all
events from level 7 to level 0.)
Example
This example will send email alerts for system errors from level 3 through 0.
Console(config)#logging sendmail level 3
Console(config)#
Chapter 4
– 161 –
| System Management Commands
(page
154). Messages sent include
SMTP Alerts