Delay Measure Operations - Edge-Core AS6700-32X Cli Reference Manual

10g/40g top-of-rack switches
Hide thumbs Also See for AS6700-32X:
Table of Contents

Advertisement

Chapter 24
| CFM Commands

Delay Measure Operations

Delay Measure Operations
ethernet cfm delay-
measure two-way
Table 141: show fault-notify-generator - display description
Field
Description
Alarm Time
The time a defect must exist before a fault alarm is issued (see the
fault-notify
Reset Time
The time after a fault alarm has been issued, and no defect exists, before
another fault alarm can be issued (see the
command).
This command sends periodic delay-measure requests to a specified MEP within a
maintenance association.
Syntax
ethernet cfm delay-measure two-way [src-mep source-mpid] {dest-mep
destination-mpid | mac-address} md domain-name ma ma-name
[count transmit-count] [interval interval] [size packet-size] [timeout timeout]
source-mpid – The identifier of a source MEP that will send the delay-
measure message. (Range: 1-8191)
destination-mpid – The identifier of a remote MEP that is the target of the
delay-measure message. (Range: 1-8191)
mac-address – MAC address of a remote MEP that is the target of the delay-
measure message. This address can be entered in either of the following
formats: xx-xx-xx-xx-xx-xx or xxxxxxxxxxxx
domain-name – Domain name. (Range: 1-43 alphanumeric characters)
ma-name – Maintenance association name. (Range: 1-43 alphanumeric
characters)
count – The number of times to retry sending the message if no response is
received before the specified timeout. (Range: 1-5)
interval – The transmission delay between delay-measure messages.
(Range: 1-5 seconds)
packet-size – The size of the delay-measure message. (Range: 64-1518
bytes)
timeout - The timeout to wait for a response. (Range: 1-5 seconds)
Default Setting
Count: 5
Interval: 1 second
Size: 64 bytes
Timeout: 5 seconds
Command Mode
Privileged Exec
alarm-time, command).
– 720 –
(Continued)
mep
mep fault-notify reset-time

Hide quick links: