Cable Diagnostics - Edge-Core AS6700-32X Cli Reference Manual

10g/40g top-of-rack switches
Hide thumbs Also See for AS6700-32X:
Table of Contents

Advertisement

Cable Diagnostics

test loop internal
show loop internal
This command performs an internal loop back test on the specified port.
Syntax
test loop internal interface interface
interface
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-32/54)
Command Mode
Privileged Exec
Command Usage
Loopback testing can only be performed on a port that is not linked up. The
internal loopback makes it possible to check that an interface is working
properly without having to make any network connections.
When performing an internal loopback test, packets from the specified
interface are looped back into its internal PHY. Outgoing data is looped back to
the receiver without actually being transmitted.
Example
Console#test loop internal interface ethernet 1/1
Internal loopback test: succeeded
Console#
This command shows the results of a loop back test.
Syntax
show loop internal interface [interface]
interface
ethernet unit/port
unit - Stack unit. (Range: 1)
port - Port number. (Range: 1-32/54)
Command Mode
Privileged Exec
– 387 –
Chapter 10
| Interface Commands
Cable Diagnostics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

As5700-54x

Table of Contents