Download Print this page
Edge-Core AS6712-32X Quick Start Manual

Edge-Core AS6712-32X Quick Start Manual

32-port 40g fiber ethernet switch

Advertisement

Available languages

Available languages

Quick Links

Quick Star t Guide
32-Port 40G Fiber Ethernet Switch
AS6712-32X | AS6812-32X
1. Unpack the Switch and Check Contents
Rack Mounting Kit—2 front-post brackets, 2 rear-post
brackets, 20 screws, and 2 ear-locking screws
Power Cord (included with AC PSUs only)
Ground Wire (included with DC PSUs only)
Console Cable—RJ-45 to DB-9
DC Power Cable (included with 48 VDC PSU only)
Documentation—Quick Start Guide (this document)
and Safety and Regulatory Information
Warning:
For a safe and reliable installation, use only the
accessories and screws provided with the AS6712-32X,
AS6812-32X. Use of other accessories and screws could
result in damage to the unit. Any damages incurred by
using unapproved accessories are not covered by the
warranty.
Avertissement:
Avertissement: Pour une installation sûre
et fiable, utilisez uniquement les accessoires et les vis
fournies avec le AS6712-32X,AS6812-32X. L'utilisation
d'autres accessoires et vis pourrait endommager l'appareil.
Les dommages causés par l'utilisation d'accessoires non
approuvés ne sont pas couverts par la garantie.
Note:
The switch has the Open Network Install
Environment (ONIE) software installer pre-loaded, but no
switch software image pre-loaded. Information about
compatible switch software can be found at
www.edge-core.com.
Caution:
The switch includes plug-in power supply (PSU)
and fan tray modules that are installed into its chassis. All
installed modules must have a matching airflow direction.
That is, if the installed power modules have a front-to-back
(F2B) airflow direction, all the installed fan tray modules
must also have a F2B airflow direction.
Attention:
Le commutateur comprend des modules
d'alimentation et de bac de ventilateurs installés sur son
châssis. Tous les modules installés doivent avoir une
direction de circulation d'air correspondante. C'est-à-dire
que tous les modules doivent avoir la même direction de
circulation d'air: avant vers arrière (F2B), ou arrière vers
avant (B2F).
Note:
The switch drawings in this document are for
illustration only and may not match your particular switch
model.
www.edge-core.com
AS6712-32X or
AS6812-32X
– 1 –
2. Attach the Brackets
1
3
1
Attach each of the front- and rear-post brackets to the
switch using four of the included bracket screws.
2
Use an additional two screws to secure each of the rear-post
brackets at the mid-point on the sides of the switch.
3
Use the screws and cage nuts supplied with the rack to
secure the switch in the rack.
Caution:
Installing the switch in a rack requires two
people. One person should position the switch in the rack,
while the other secures it using the rack screws.
Attention:
Deux personnes sont nécessaires pour installer
un commutateur dans un bâti : La première personne va
positionner le commutateur dans le bâti, la seconde va le
fixer avec des vis de montage.
装置の吸排気に必要な領域を マニ ュ アル上に規定 し て
い る 。
3. Adjust Rear-Post Bracket Ears
1
Lock the position of the rear-post bracket ears using the
included position-locking screws.
You can also adjust the rear-post bracket ears to fit different
rack depths from 56 cm to 75 cm.
1
2
1
E122019-AP-R04
150200001635A

Advertisement

loading
Need help?

Need help?

Do you have a question about the AS6712-32X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Edge-Core AS6712-32X

  • Page 1 Warning: For a safe and reliable installation, use only the secure the switch in the rack. accessories and screws provided with the AS6712-32X, AS6812-32X. Use of other accessories and screws could Caution: Installing the switch in a rack requires two result in damage to the unit.
  • Page 2: Ground The Switch

    4. Ground the Switch Caution: Use a UL/IEC/EN 60950-1 certified power supply to connect to a DC converter, and a #14 AWG (for 36–75 VDC PSU) or #10 AWG (for 12 VDC PSU) wire to connect to a DC PSU. Attention: Utilisez une alimentation certifiée UL/IEC/EN 60950-1 pour le connecter à...
  • Page 3: Hardware Specifications

    438.4 x 515 x 43.5 mm (17.26 x 20.28 x 1.73 inches) 9. View the Product Label Weight AS6712-32X: 9.135 kg (20.12 lb), with two PSUs AS6812-32X: 9.025 kg (19.9 lb), with two PSUs Temperature Operating: 0° C to 40° C (32° F to 104° F) Storage: -40°...
  • Page 4 快 速 入 门 指 南 32 端口 40G 以太网交换机 AS6712-32X | AS6812-32X 使用另外两个螺丝将每个后柱支架固定到交换机侧面上 1. 打开交换机的包装并检查内装物 的中间点。 AS6712-32X 或 使用机架随附的螺丝和卡式螺母将交换机固定到支架 上。 AS6812-32X 小心:将此交换机安装在机架中时需要两个人。一个人 将交换机放置在机架中,同时另一个人用机架螺丝将其 前柱支架 x2, 带可调节吊耳的后柱支架 x2, 支架螺丝 固定。 x20, 后支架吊耳位置 - 锁定螺丝 x2 装置の吸排気に必要な領域を マニ ュ アル上に規定 し て...
  • Page 5 快速入门指南 启动交换机。等待 ONIE 软件找到和执行 NOS 安装程 5. 连接电源 序,然后等待安装程序加载 NOS 软件映像。 以后交换机启动时将跳过 ONIE 而直接运行 NOS 软件。 注意: 有关 ONIE 软件位置选项和设置的详细信息,请 参见 NOS 安装程序和 NOS 文档。 8. 连接网线 在交换机上安装 1 个或 2 个 AC 或 DC 电源模块。 本交换 机可使用最多 2 个 PSU,且 PSU 的气流方向必须与安装 的风扇框相同。...
  • Page 6 438.4 × 515 × 43.5 mm ( 宽 x 深 x 高 ) (17.26 × 20.28 × 1.73 英寸 ) 重量 AS6712-32X: 9.135 kg (20.12 磅 ),含附带的两 个 PSU AS6812-32X: 9.025 kg (19.9 磅 ), 含附带的两个 温度 运转时:0 ℃ 至 40 ℃ (32 ℉ 至 104 ℉ ) 储存时:-40 ℃...
  • Page 7 快速入門指南 32 埠 40G 乙太網路交換機 AS6712-32X | AS6812-32X 使用隨機櫃提供的螺絲及籠罩螺帽,將交換器固定在機 1. 拆開交換器包裝並檢查內容物 櫃上。 注意: 需要兩個人,將交換器裝到機櫃上。一人負責固 AS6712-32X 或 定交換器在機櫃上之位置,另一人負責用機櫃螺絲固 AS6812-32X 定。 装置の吸排気に必要な領域を マニ ュ アル上に規定 し て 前柱托架 x2、後柱托架附可調固定片 x2、托架螺 い る 。 絲 x20、後托架固定片位置-定位螺絲 x2 電源線 (僅隨附於 AC PSU) 3. 調整後柱托架固定片...
  • Page 8 快速入門指南 5. 連接電源 啟動交換器。等待 ONIE 軟體找尋並執行 NOS 安裝程 式,並等待安裝程式載入 NOS 軟體映像檔。 之後交換器啟動時,會跳過 ONIE,直接運行 NOS 軟 體。 關於詳細軟體選項及 ONIE 設定說明,請參閱網 說明: 路作業系統 (NOS)安裝程式及 NOS 文件。 8. 連接網路線 在交換器上安裝 1 個或 2 個 AC 或 DC 電源模組 。 本交換 器可使用最多 2 個 PSU,且 PSU 的氣流方向必須與安裝 的風扇框相同。...
  • Page 9 交換器機箱 438.4 x 515 x 43.5 mm 尺寸 (WxDxH) (17.26 x 20.28 x 1.73 英吋) AS6712-32X: 9.135 kg (20.12 lb) ,含兩個安 重量 裝 PSU AS6812-32X: 9.025 kg (19.90 lb) ,含兩個安 裝 PSU 操作 : 0° C 至 40° C (32° F 至 104° F)...

This manual is also suitable for:

As6812-32x