This example shows the configuration status for continuity check and cross-check
traps.
Console#show ethernet cfm configuration traps
CC MEP Up Trap
CC MEP Down Trap
CC Configure Trap
CC Loop Trap
Cross Check MEP Unknown Trap :Disabled
Cross Check MEP Missing Trap :Disabled
Cross Check MA Up
Console#
Table 134: show ethernet cfm configuration traps - display description
Field
Description
CC MEP Up Trap
Sends a trap if a remote MEP is discovered and added to the local
database, the port state of a previously discovered remote MEP changes,
or a CCM is received from a remote MEP which as an expired entry in the
archived database.
CC Mep Down Trap
Sends a trap if this device loses connectivity with a remote MEP, or
connectivity has been restored to a remote MEP which has recovered from
an error condition.
CC Configure Trap
Sends a trap if this device receives a CCM with the same MPID as its own
but with a different source MAC address, indicating that a CFM
configuration error exists.
CC Loop Trap
Sends a trap if this device receives a CCM with the same source MAC
address and MPID as its own, indicating that a forwarding loop exists.
Cross Check MEP
A CCM is received from a MEP that has not been configured as a DSAP (see
Unknown Trap
the
(see the
CCM messages.
Cross Check MEP Missing
This device failed to receive three consecutive CCMs from another MEP in
Trap
the same MA.
Cross Check MA Up
Generates a trap when all remote MEPs belonging to an MA come up.
This example shows the CFM status for port 1.
Console#show ethernet cfm configuration interface ethernet 1/1
Ethernet 1/1 CFM Status:Enabled
Console#
:Disabled
:Disabled
:Disabled
:Disabled
:Disabled
ethernet cfm mep
command), manually configured as a remote MEP
mep crosscheck mpid
command), nor learned through previous
– 695 –