End of Read Cycle
Read Cycle Timeout
Usage:
Useful in many tightly controlled applications which require a read cycle to
end before the next object appears and therefore need the flexibility of a
timeout adjustment.
Definition:
Read Cycle Timeout is the time span of the read cycle and is represented in
10 ms increments. It is used in conjunction with External Edge or Serial
Trigger.
Serial Cmd: <K220,end of read
100
Default:
(x 10 ms)
Options:
0 to 65535. (Divide any positive number entered by 100 to determine the time
in seconds.)
Note: A minimum setting of 2 is recommended.
Note: Timeout or Timeout or New Trigger under End of Read Cycle must
be enabled for Read Cycle Timeout to take effect.
4-16
cycle,read cycle
timeout>
MS-890 Industrial Automation Scanner User Manual