Configurable Output 1
Output State
Definition:
Sets the active electrical state of the discrete output.
Serial Cmd:
< K810,output
Negative
Default:
0 = Negative
Options:
Pulse Width
Sets the time in 10 ms increments that the discrete output remains active.
Definition:
Serial Cmd:
< K810,output on,output
Default:
50
1 to 65535 (Divide the number entered on the command line by 100 for time
Options:
in seconds)
Output Mode
Definition:
Sets the condition in which the discrete output is de-activated.
< K810,output on,output state,pulse
Serial Cmd:
Pulse
Default:
Options:
0 = Pulse
1 = Latch Mode 1
2 = Latch Mode 2
3 = Latch Mode 3
Pulse
This is the default mode of operation in which the programmable output is activated when
the Output On condition has been met and held active for the duration of the selected
pulse width.
Latch Mode 1 (Unlatch on Input 1 Pin)
In this mode the programmable output will be activated when the Output On condition is
met. It will stay active until the state of the Input 1 pin changes from inactive to active or
the proper mode is configured using the EZ Button.
Important: To unlatch using the
puts". To unlatch using the
Latch Mode 2 (Unlatch Opposite Condition)
The programmable output is activated when the Output On condition has been met and
held active until the opposite condition selected under Output On has been met.
For example, if No Read is enabled under Output On, the programmable output will go
active on a No Read and remain active until the opposite condition, a Good Read, occurs.
6-22
on,output
state,pulse width,output mode >
1 = Positive
state,pulse
Input 1
pin, the input status must be set to "Unlatch Out-
EZ
Button, the button status must be set to Unlatch Mode.
MS-890 Industrial Automation Scanner User Manual
width,output mode >
width,output mode
>