Microscan MS-890 User Manual page 103

Industrial automation scanner
Table of Contents

Advertisement

Application Record Brackets Status (EAN-128)
When enabled, parentheses ( ) are added to enclose application identifiers.
Definition:
Serial Cmd:
<K474,Code 128 status,fixed symbol length status,symbol length,EAN-128
status,output format,application record separator status,application record
separator
record padding status,minimum ratio distance>
Default:
Disabled
Options:
0 = Disabled
Note: Output Format must be set to Application Record before this parameter can take effect.
Application Record Padding Status (EAN-128)
Definition:
Padding is the insertion of zeros to make up the maximum length of a variable
application record data field, except for the last field which does not require
padding.
When enabled, padding is included. When disabled, padding is omitted.
Note: Padding is never added to fixed length fields or to the last data field of
a symbol. Enabling or disabling Record Padding will have no effect on
these.
<K474,Code 128 status,fixed symbol length status,symbol length,EAN-128
Serial Cmd:
status,output format,application record separator status,application record
separator character,application record brackets
padding
Disabled
Default:
0 = Disabled
Options:
Note: Output Format must be set to Application Record before this parameter can take
effect.
Minimum Ratio Distance (Code 128)
Definition:
Determines the error tolerance level.
Normal enforces a requirement for normal error tolerance.
High enforces a requirement for high element-to-element quality.
Highest enforces a requirement for very high element-to-element quality.
Serial Cmd:
<K474,Code 128 status,fixed symbol length status,symbol length,EAN-128
status,output format,application record separator status,application record
separator character,application record brackets status,application record
padding
Default:
Normal
Options:
0 = Normal
MS-890 Industrial Automation Scanner User Manual
character,application record brackets
1 = Enabled
status,minimum ratio distance>
1 = Enabled
status,minimum ratio
1 = High
status,application
status,application record
distance>
2 = Highest