Optoelectric Control
Optoelectric Control
Note: Optoelectic Control requires the assembly of a Configuration Database.
Optoelectric Control Mode
Usage:
Useful where different symbol types, sizes, qualities or distances require
more that one optical setup (focus, gain, and tracking) for dynamic optical
changes.
Definition:
A database index of up to seven pre-defined optical indexes of settings
defining focus, gain, and tracking can be accessed and applied in the following
modes:
• A timer in which all settings cycle throughout the time duration.
• An automatic search for the best database index.
• A combination of up to three control trigger inputs to dynamically select
the optimum database index.
The index settings can also be saved and recalled selectively, or reviewed
with a Request Database Settings command.
Serial Cmd:
<K226,mode,# active database settings,latch on trigger,timer/switch
value,control trigger 1 status,control trigger 2 status,control trigger 3 status,
database cycles>
Default:
Disabled
Options:
0 = Disabled
1 = Control Trigger
2 = Automatic/Static Mode
3 = Timer
4 = Number of Raster Sweeps
Disabled
Definition:
When disabled, the scanner uses the standard configuration settings that
are set in the Calibration tree and shown to the right of Standard in the
Database Index.
Serial Cmd:
<K226,mode,# active database settings,latch on trigger,timer/switch
value,control trigger 1 status,control trigger 2 status,control trigger 3 status,
database cycles>
9-8
MS-890 Industrial Automation Scanner User Manual