Mismatch Replace
Provides a convenient shortcut for applications that need to output a
Usage:
predefined text string whenever a symbol does not match a master
symbol.
Definition:
Outputs a user-defined data string whenever a mismatch occurs and
Matchcode is enabled.
<K736,status,replacement string>
Serial Cmd:
Default:
Disabled
Options:
0 = Disabled
Replacement String
Definition:
User-defined data string that, when enabled, replaces symbol data
whenever a mismatch occurs.
Serial Cmd:
<K736,status,replacement
Default:
MISMATCH
Options:
1 to 128 ASCII characters
MS-890 Industrial Automation Scanner User Manual
1 = Enabled
string>
Matchcode