Advanced Calibration Features - Microscan MS-890 User Manual

Industrial automation scanner
Table of Contents

Advertisement

Advanced Calibration Features

Advanced Calibration Features
In the Advanced tab in the Calibration menu you can constrain the scan width of the scan
beam with Laser Framing and set up the rules the scanner will follow during calibration procedure.
See
Laser Framing
Auto Range
Usage:
Enabling Auto Range improves focus acquisition speed where extraneous
objects are not mistaken for symbols.
Definition:
With Auto Range enabled, the scanner will focus outward and not begin
the calibration routine until an object is detected by signal strength.
<K510,auto
Serial Cmd:
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Using Auto Range
1. Be sure there are no extraneous objects between the symbol and the scanner.
2. Click on the Advanced tab in the Calibration menu.
3. If Auto Range is not enabled, click on it to enable it.
4. Click the Calibrate button to start calibration.
5. Examining the read rates in the Results graph following calibration.
9-14
on page 10-7 for information on laser framing.
range,starting focus position,focus step size>
MS-890 Industrial Automation Scanner User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-890 and is the answer not in the manual?

Questions and answers

Table of Contents