Autodiscriminate
Although Autodiscriminate is not a configuration command, but it is included here as a
convenient tool for enabling most symbol types.
Usage:
Commonly used for quick setup mode to detect symbol type. This is particularly
useful for users who might be unfamiliar with their application's symbology.
Note: It does not alter individual fields such as Start/Stop, Fixed Length,
etc. These need to be setup individually.
Enables all available symbology types except PDF417, UPC/EAN, and
Definition:
Pharmacode. The user may also individually disable/enable each symbology
type.
Serial Cmd:
<P>
Default:
Code 39
<P>
Options:
<Q>
<R>
<S>
Note: If using an I 2/5 symbol, verify that the number of characters in the symbol being
scanned matches the symbol length enabled for the I 2/5 symbol type (default is 10 and 6).
MS-890 Industrial Automation Scanner User Manual
(only)
Enables all codes except noted above.
Enables Code 39 only
Enables Codabar only
Enables I 2/5 only
Symbologies
5-27