Trigger

Trigger Mode
Note: When doing calibration or read rate testing, the current trigger setting will be disregarded.
Note: This command does not need to be followed by an
The type of trigger event that will initiate the read cycle.
Definition:
<K200,trigger
Serial Cmd:
Continuous Read
Default:
0 = Continuous Read
Options:
1 = Continuous Read 1 Output
2 = External Level
3 = External Edge
4 = Serial Data
5 = Serial Data and External Edge
Continuous Read
Continuous Read is useful in testing symbol readability or scanner functions. It
Usage:
is not recommended for normal operations.
In Continuous Read, trigger input options are disabled, the scanner is
Definition:
always in the read cycle, and it will attempt to decode and output every scan
crossing a symbol. When To Output and No Read options have no effect on
Continuous Read.
Serial Cmd: <K200,0>
MS-890 Industrial Automation Scanner User Manual
mode,trigger filter duration>
<A>
command.
Read Cycle