Interleaved 2 of 5
Guard Bar (Interleaved 2 of 5)
Note: Whenever Guard Bar is enabled, the presence of guard bars is required for decoding
to take place.
Usage:
Useful when I 2 of 5 multisymbols are enabled to prevent false data out-
put. This typically occurs with highly tilted or skewed symbols.
Definition:
A guard bar is a heavy bar, at least 2 times the width of the wide bar, surrounding
the printed I 2 of 5 symbol and helping to prevent false reads.
Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length #1,
symbol length
Disabled
Default:
Options:
0 = Disabled
1 = Enabled
Range Mode (Interleaved 2 of 5)
Note: Whenever Guard Bar is enabled, the presence of guard bars is required for decoding
to take place.
Definition:
When enabled, this feature causes symbol length # 1 and symbol length # 2
to form of a range of lengths that can be decoded.
For example, if symbol lengths of 10 and 6 are enabled, those are the
lengths that can be decoded. Note that either length can serve as the minimum
or maximum.
Serial Cmd:
<K472,status,check digit status,check digit output status,symbol length #1,
symbol length #2,guard
Disabled
Default:
0 = Disabled
Options:
1 = Enabled
5-12
#2,guard
bar,range mode>
bar,range