Calibrate
Step 8 — Calibrate
1. Click the Calibration button in EZ Mode or in the Calibration view.
2. Allow some time for the scanner to cycle through the focus, gain, and tracking settings.
Do not move or disturb the scanner or test symbol while calibration is in progress.
3. When calibration is complete, the settings that provided the highest read rate will be
selected. You will see one of the following messages: Calibration Passed, Calibration
Failed, or Original Settings Were Optimal.
Note: To silence the beeper, interrupt scanning by removing or blocking the test
symbol, or send a
If calibration fails, try the following:
1. Check the read range for your particular symbol density.
2. Examine symbol quality and try a different sample symbol.
3. Slightly skew or tilt the symbol or scanner to minimize specular reflection.
4. Verify that the correct symbology is enabled.
1-10
<K702,0>
command to disable the beeper.