External Trigger State

Note: External Level, External Edge, or Serial Data and External Edge trigger mode
must be enabled for External Trigger to take effect.
Users can select the trigger state that will operate with their systems. (If using
Usage:
an object detector, use Active Closed.)
When enabled for Active Closed the triggering device imposes a current on
Definition:
the optoisolator to activate the read cycle. When enabled for Active Open
the triggering device interrupts the current to the optoisolator to activate the
read cycle.
<K202,external trigger
Serial Cmd:
Active closed
Default:
Options:
0 = Active open
MS-890 Industrial Automation Scanner User Manual
state>
1 = Active closed
Read Cycle
4-11