Using Master Symbols

Using Master Symbols
1. Set Triggering Mode to External or Serial (see
2. Set Matchcode Type to an option that fits your application (see
on page 7-5).
3. Define the output you want with your matchcode setup:
a) Data output
b) Discrete output (see
4. Select the number of master symbols you want to create. If more than one, send a
<K224,number of master symbols> command (see
5. Enter master symbol data in one of the following ways:
a) Use ESP to type in master symbol data directly into the Utilities menu.
b) Send a serial command with symbol data in the form of
data>
(or
<) data)>
c) Send a
<Gmaster symbol number>
master symbol.
d) Enable the New Master Pin command and activate a discrete input to store the
next symbol scanned as the master symbol (see
7-4
(Symbol Data Output
Configurable Output 1
for single master symbol only).
Trigger
on page 4-5).
on page 6-4).
on page 6-20).
Master Database
command to scan the next symbol as the
New Master Pin
MS-890 Industrial Automation Scanner User Manual
Matchcode Type
on page 12-11).
<Mmaster symbol#,
on page 7-11).