Counts
(This command is Read-Only.)
Power-Ons
Definition
Returns the number of times the scanner has been re-powered or a watchdog
reset occurs.
Serial Cmd:
Send: <K406?>
Returns: <K406,power-ons,resets,parameter saves>
Read-Only
0 to 65535 power-ons.
Range:
Resets
Usage:
Used for detecting unwanted resets caused by power supply problems or
ESD transients.
Definition
Resets include watchdog reset,
defaults. A watchdog reset is a reset that is forced whenever the software
locks up.
Serial Cmd:
Send: <K406?>
Returns: <K406,power-ons,resets,parameter saves>
Read-Only
0 to 65535 resets.
Range:
Parameter Saves
Definition
Returns the number of times parameters are written to memory, including
<Z>
Serial Cmd:
Send: <K406?>
Returns:
Read-Only
0 to 65535 saves.
Range:
MS-890 Industrial Automation Scanner User Manual
commands and hardware defaults.
<K406,power-ons,resets,parameter
<A>
<Z>
and
commands, and hardware
saves>
Diagnostics
8-3
Need help?
Do you have a question about the MS-890 and is the answer not in the manual?