Mounting The Transmitter - Siemens SITRANS FC430 Operating Instructions Manual

Coriolis flowmeters
Hide thumbs Also See for SITRANS FC430:
Table of Contents

Advertisement

Installing/mounting
4.2 Installation instructions
4.2.1.1

Mounting the transmitter

1. Remove locking cap from mounting bracket.
2. Mount transmitter on mounting bracket taking care that the flutes on the mating faces are
correctly engaged.
3. Firmly tighten locking cap on mounting bracket (torque: 25 Nm).
4.2.1.2
Turning the transmitter
Horizontal rotation
1. Unscrew cap from lock screw.
2. Loosen lock screw at transmitter pedestal using 5 mm Allen key.
3. Carefully rotate transmitter into desired position.
4. Firmly tighten lock screw (torque: 10 Nm).
5. Replace cap onto lock screw (torque: 10 Nm).
46
FC430 (From firmware 4.0)
Operating Instructions, 06/2017, A5E39789392-AA