Design - Siemens SITRANS FC430 Operating Instructions Manual

Coriolis flowmeters
Hide thumbs Also See for SITRANS FC430:
Table of Contents

Advertisement

Description
Transmitter pedestal lock screw
Pedestal lock screw cap
Cable gland to housing (Siemens supplied, metric)
Note
NPT glands
When using NPT glands, the user must take care to use the supplied NPT thread adaptors.
11.6.1

Design

Sensor design
Table 11-19 Sensor design
Description
Dimension and weight
Process connectors
Electrical connection
Material
FC430 (From firmware 4.0)
Operating Instructions, 06/2017, A5E39789392-AA
Measuring tubes
Compact version:
Remote version:
Specification
See "Dimensions and weight"
● EN1092-1 B1, PN16, PN40, PN63, PN100, PN160
● EN1092-1 D (gasket groove), PN40, PN63, PN100, PN160
● ISO 228-1 G *
● ASME B1.20.1 NPT *
● ASME B16.5, Cl 150, Cl 300, Cl 600, Cl 900
● DIN 11851 **
● DIN 32676 *
● DIN 11864-1A **, DIN 11864-2C (inch) **, DIN 11864-3A **
● ISO 2852 **
● ISO 2853 **
● JIS B 2220, 10K, 20K, 40K, 62K
● M12 connector with 4-wire cable
● Standard cable with polymer / brass / stainless steel cable
glands (metric or NPT)
● Armored cable with stainless steel armored cable glands
(metric or NPT)
● Conduit entries (metric or NPT)
● AISI 316L / EN1.4404
● Hastelloy C22 / UNS N06022
Technical data
11.6 Construction
Torque (Nm)
10
6
10
10
235