Default settings
E.3 Standard volume flow
Table E-4
Density
HMI menu ID
Parameter
2.2.5.1
Units
2.2.5.2
Custom units
2.2.5.3
Custom conversion fac‐
tor
2.2.5.4
Decimal places
2.2.5.5
Alarm and warning limits
2.2.5.5.1
Upper alarm limit
2.2.5.5.2
Upper warning limit
2.2.5.5.3
Lower warning limit
2.2.5.5.4
Lower alarm limit
2.2.5.5.5
Hysteresis
2.2.5.6
Density adjustment
2.2.5.6.1
Adjustment factor
2.2.5.6.3
Adjustment offset
332
Description
Select unit for displayed density.
Unit is not applied at communi‐
cation interface.
Define a name for the custom
units. The custom units can then
be selected in the units list.
Define a mass flow factor for the
custom units. The factor is
based on SI mass flow units kg/
s
Define the decimal point for the
process value displayed in the
Local User Interface.
Set upper alarm limit. Alarm is
triggered if density value is
above the limit.
Set upper warning limit. Warning
is triggered if density value is
above the limit.
Set lower warning limit. Warning
is triggered if density value is be‐
low the limit.
Set lower alarm limit. Alarm is
triggered if density value is be‐
low the limit.
Sets the hysteresis for alarm
and warning limits. The hystere‐
sis is the distance between the
limits for activation and deactiva‐
tion of alarm/warning.
Set compensation factor to ad‐
just density calculation.
Enter the displayed density ad‐
justment offset.
Default value
Value range
[unit]
kg/m³
µg/L, µg/m³, mg/
L, g/mL, g/cm³, g/
L, kg/L, kg/m³, lb/
in³, lb/gal, lb/ft³,
STon/yd³, Custom
1)
1)
1)
1)
2
● Auto
● No decimal
place
● 1
● 2
● 3
● 4
● 5
● 6
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1
-1.999 to1.999
0
-14000.0 to
[kg/m³]
14000.0
FC430 (From firmware 4.0)
Operating Instructions, 06/2017, A5E39789392-AA
Access
level
User
User
User
User
User
User
User
User
User
Expert
Expert