Inputting, Modifying, and Checking the Program
Example

4-7-4 Displaying the Cycle Time

Example
98
The following example shows some of the displays that can appear as a result of
a program check.
00000
00000PROG CHK
CHKLVL
00064PROG CHK
Halts program check
00699CHK ABORTD
Check continues until END(01)
02000PROG CHK
END (01)(02.7KW)
When errors are found
00178CIRCUIT ERR
OUT
00200IL-ILC
ILC (03)
02000NO END INST
END
Once the program has been cleared of syntax errors, the cycle time should be
checked. This is possible only in RUN or MONITOR mode while the program is
being executed. See Section 6 Program Execution Timing for details on the
cycle time.
To display the current average cycle time, press CLR then MONTR. The time
displayed by this operation is a typical cycle time. The differences in displayed
values depend on the execution conditions that exist when MONTR is pressed.
(0-2)?
00200
ERR
00000
00000SCAN TIME
054.1MS
00000SCAN TIME
053.9MS
Section 4-7
Display #1
Display #2
Display #3