Sysmac Net/Sysmac Link System - Omron SYSMAC C200HS Operation Manual

Programmable controllers
Hide thumbs Also See for SYSMAC C200HS:
Table of Contents

Advertisement

SR Area
Word(s)
Bit(s)
00
273
01
02 to 11
12
13
14
15
274
00
01
02
03
04
05
06
07
08
09
10 to 15
00
275
01
02
03 to 15
00 to 07
276
08 to 15
277 to 279
00 to 15
280 to 289
00 to 15
290 to 293
00 to 15
294 to 297
00 to 15
298 to 299
00 to 15

3-4-1 SYSMAC NET/SYSMAC LINK System

Loop Status
–––
Level 0
07
06
Level 1
15
14
Status/
1
1
Central Power Supply
Meaning
0: Connected
1: Not connected
Completion Codes
Save IOM to Cassette Bit
Load IOM from Cassette Bit
Reserved by system (not accessible by user)
Transfer Error Flag: Not
PROGRAM mode
Transfer Error Flag: Read Only
Transfer Error Flag: Insufficient
Capacity or No IOM
Transfer Error Flag: Checksum
Error
Special I/O Unit #0 Restart Flag
Special I/O Unit #1 Restart Flag
Special I/O Unit #2 Restart Flag
Special I/O Unit #3 Restart Flag
Special I/O Unit #4 Restart Flag
Special I/O Unit #5 Restart Flag
Special I/O Unit #6 Restart Flag
Special I/O Unit #7 Restart Flag
Special I/O Unit #8 Restart Flag
Special I/O Unit #9 Restart Flag
Reserved by system (not accessible by user)
PC Setup Startup Error (DM 6600 to DM 6614)
PC Setup RUN Error (DM 6615 to DM 6644)
PC Setup Communications/Error Setting/Misc. Error (DM 6645 to DM 6655)
Reserved by system (not accessible by user)
Minutes (00 to 59)
Hours (00 to 23)
Used for keyboard mapping. See page 368.
Reserved by system (not accessible by user)
Macro Area inputs.
Macro Area outputs.
Reserved by system (not accessible by user)
SR 236 provides the local node loop status for SYSMAC NET Systems, as
shown below.
05
04
13
12
1
Loop Status
11: Normal loop
10: Downstream backloop
01: Upstream backloop
00: Loop error
SR 23700 to SR23707 provide the SEND/RECV completion code for operating
level 0 and SR 23708 to SR 23215 provide the SEND/RECV completion code for
operating level 1. The completion codes are as given in the following tables.
Function
Data transferred to Memory Cassette when Bit is turned
ON in PROGRAM mode. Bit will automatically turn OFF.
ON in PROGRAM mode. Bit will automatically turn OFF.
An error will be produced if turned ON in any other
mode.
Data will not be transferred from IOM to the Memory
Cassette if an error occurs (except for Read Only Error).
These flags will turn ON during restart processing.
g
These flags will not turn ON for Units on Slave Racks.
Th
fl
ill
Used for time increments.
Bit in SR 236
03
02
11
10
Section 3-4
(
p
y
g
p
g
ON f
U i
Sl
R
k
01
09
Reception Status
0: Reception enabled
1: Reception disabled
)
00
08
1
37