Omron SYSMAC C200HS Operation Manual page 461

Programmable controllers
Hide thumbs Also See for SYSMAC C200HS:
Table of Contents

Advertisement

Memory Areas
AR Area
Word(s)
Bit(s)
00
00 to 09
10
11
12
13
14
15
01
00 to 09
10
11
12, 13
14
15
02
00 to 04
05 to 14
15
03
00 to 15
04
00 to 15
05
00 to 15
06
00 to 15
07
00 to 03
04 to 07
08
09
10 and 11
12
13
14
15
08 to 11
00 to 15
12 to 15
00 to 15
16
00 to 15
17
00 to 15
18
00 to 07
Writeable
08 to 15
19
00 to 07
Writeable
08 to 15
20
00 to 07
Writeable
08 to 15
21
00 to 07
Writeable
Writeable
08 to 12
13
14
15
22
00 to 15
458
Error Flags for Special I/O Units 0 to 9 (also function as Error Flags for PC Link Units)
Error Flag for operating level 1 of SYSMAC LINK or SYSMAC NET Link System
Error Flag for operating level 0 of SYSMAC LINK or SYSMAC NET Link System
Host Computer to Rack-mounting Host Link Unit Level 1 Error Flag
Host Computer to Rack-mounting Host Link Unit Level 0 Error Flag
Remote I/O Master Unit 1 Error Flag
Remote I/O Master Unit 0 Error Flag
Restart Bits for Special I/O Units 0 to 9 (also function as Restart Bits for PC Link Units)
Restart Bit for operating level 1 of SYSMAC LINK or SYSMAC NET Link System
Restart Bit for operating level 0 of SYSMAC LINK or SYSMAC NET Link System
Not used.
Remote I/O Master Unit 1 Restart Flag.
Remote I/O Master Unit 0 Restart Flag.
Slave Rack Error Flags (#0 to #4)
Group-2 High-density I/O Unit Error Flags
Group-2 High-density I/O Unit Error Flag
Error Flags for Optical I/O Units 0 to 7
Error Flags for Optical I/O Units 8 to 15
Error Flags for Optical I/O Units 16 to 23
Error Flags for Optical I/O Units 24 to 31
Data Link setting for operating level 0 of SYSMAC LINK System
Data Link setting for operating level 1 of SYSMAC LINK System
Normal TERMINAL Mode/Expansion TERMINAL Mode Input Cancel Bit
Expansion TERMINAL Mode Changeover Flag
Reserved by system.
Terminal Mode Flag
ON: Expansion; OFF: Normal (Same as status of pin 6 on CPU's DIP switch)
Error History Overwrite Bit
Error History Reset Bit
Error History Enable Bit
Active Node Flags for SYSMAC LINK System nodes of operating level 0
Active Node Flags for SYSMAC LINK System nodes of operating level 1
SYSMAC LINK/SYSMAC NET Link System operating level 0 service time per cycle
SYSMAC LINK/SYSMAC NET Link System operating level 1 service time per cycle
Seconds: 00 to 99
Minutes: 00 to 59
Hours: 00 to 23 (24-hour system)
Day of Month: 01 to 31 (adjusted by month and for leap year)
Month: 1 to 12
Year: 00 to 99 (Rightmost two digits of year)
Day of Week: 00 to 06 (00: Sunday; 01: Monday; 02: Tuesday; 03: Wednesday; 04:
Thursday; 05: Friday; 06: Saturday)
Not used.
30-second Compensation Bit
Clock Stop Bit
Clock Set Bit
Keyboard Mapping
Function
Appendix D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents