UM Area Data
Word
Bit(s)
00
SR 270
01
02
03
04 to 11
12
13
14
15
00 to 07
SR 271
08 to 15
00 to 10
SR 272
11
12
13
14
15
SR273
00
01
02 to 11
12
13
14
9-3
UM Area Data
Writing Data
1, 2, 3...
Save UM to Cassette Bit
Load UM from Cassette Bit
Collation Execution Flag
Collation NG Flag
Reserved by system (not accessible by user)
Transfer Error Flag: Not
PROGRAM mode
Transfer Error Flag: Read Only
Transfer Error Flag: Insufficient
Capacity or No UM
Transfer Error Flag: Board
Checksum Error
Ladder program size stored in Memory Cassette
Ladder-only File: 04: 4 KW; 08: 8 KW; 12: 12 KW; ... (64: 64 KW)
00: No Ladder program or no file
Data updated at data transfer from CPU at startup. The file must begin in segment 0.
Ladder program size and type in CPU (Specifications are the same as for bits 00 to 07.)
Reserved by system (not accessible by user)
Memory Error Flag: PC Setup Checksum Error
Memory Error Flag: Ladder Checksum Error
Memory Error Flag: Instruction Change Vector Area Checksum Error
Memory Error Flag: Memory Cassette Online Disconnection
Memory Error Flag: Autoboot Error
Save IOM to Cassette Bit
Load IOM from Cassette Bit
Reserved by system (not accessible by user)
Transfer Error Flag: Not
PROGRAM mode
Transfer Error Flag: Read Only
Transfer Error Flag: Insufficient
Capacity or No IOM
The following procedures can be used to read UM Area data from, write UM Area
data to, and compare UM Area data on an EEPROM Memory Cassette mounted
to a C200HS CPU. This UM Area data can include the user program, fixed DM
data such as the PC Setup, expansion DM data, I/O comment data, I/O table
data, and UM Area allocation data. The procedures cannot be used to write to
EPROM Memory Cassettes, which require a PROM writer. Refer to the LSS op-
eration manuals for PROM writer procedures.
Note The data inside the Memory Cassette should be protected by turning on the
write-protect switch whenever you are not planning to write to the Cassette.
The following procedure is used to write UM Area data from the C200HS CPU to
a Memory Cassette mounted in the CPU.
1. Turn off the write-protect switch on the Memory Cassette to write-enable it.
2. Make sure that power to the C200HS CPU is turned OFF.
3. Mount the Memory Cassette to the CPU.
Function
Data transferred to Memory Cassette when Bit is turned
ON in PROGRAM mode. Bit will automatically turn OFF.
ON in PROGRAM mode. Bit will automatically turn OFF.
An error will be produced if turned ON in any other
mode.
Data will not be transferred from UM to the Memory
Cassette if an error occurs (except for Board Checksum
Error). Detailed information on checksum errors
E
) D t il d i f
ti
occurring in the Memory Cassette will not be output to
occurring in the Memory Cassette will not be output to
SR 272 because the information is not needed. Repeat
the transmission if SR 27015 is ON.
the transmission if SR 27015 is ON.
Data transferred to Memory Cassette when Bit is turned
ON in PROGRAM mode. Bit will automatically turn OFF.
ON in PROGRAM mode. Bit will automatically turn OFF.
An error will be produced if turned ON in any other
mode.
Data will not be transferred from IOM to the Memory
Cassette if an error occurs (except for Read Only Error).
Section 9-3
(
p
h
k
(
p
y
387
)

Hide quick links:

Advertisement

Table of Contents