Monitoring Operation and Modifying Data
7-1-7
8-digit Hex/Decimal Display Change
Key Sequence
3-word monitor
currently displayed.
Example
TR
[New data]
TR
356
This operation converts data displays from normal or signed, 4 or 8-digit hexa-
decimal data to decimal and vice versa.
Decimal values from 0 to 4,294,967,295 are valid when inputting normal 8-digit
hexadecimal data, and decimal values from –2,147,483,648 to +2,147,483,647
are valid when inputting signed 8-digit hexadecimal data.
TR
(NOT switches between
normal and signed data.)
cL01D000000001
8000 1234R OFF
cL01
-32768
cL02 cL01
-0000098304
cL02 cL01
4294868992
cL02 cL01
-0000098304
PRES VAL?
cL02-0000098304
PRES VAL?
cL02+0000098304
PRES VAL?
cL02+1234567890
cL02 cL01
+1234567890
cL01D000000001
02D2 1234R OFF
Rightmost four digits
[New data]
Clear new input data.
Specifies positive
signed data.
Specifies negative
signed data.
Monitor the first of the desired words.
(Leftmost word in 3-word monitor.)
Press SHIFT and TR to change the
display to signed decimal.
Press EXT to change the display to
8-digit signed decimal.
(In this case, LR 02 contains FFFE.)
Press NOT to switch back and forth
between signed and normal data.
Press CHG to change the contents of
the displayed words.
Press PLAY/SET to specify positive
signed data.
Input the new value.
(1234567890 in this case.)
Press WRITE to enter the new data to
memory.
Press SHIFT and TR to change the
display back to hexadecimal.
Section 7-1
TR