Error Flags - Omron SYSMAC C200HS Operation Manual

Programmable controllers
Hide thumbs Also See for SYSMAC C200HS:
Table of Contents

Advertisement

Error Flags

10-5 Error Flags
SR Area
Address(es)
23600 to 23615
Node loop status for SYSMAC NET Link system
23700 to 23715
Completion/error code output area for SEND(90)/RECV(98) in SYSMAC LINK/SYSMAC NET Link
System
24700 to 25015
PC Link Unit Run and Error Flags
25100 to 25115
Remote I/O Error Flags
25200
SYSMAC LINK/SYSMAC NET Link Level 0 SEND(90)/RECV(98) Error Flag
25203
SYSMAC LINK/SYSMAC NET Link Level 1 SEND(90)/RECV(98) Error Flag
25206
Rack-mounting Host Link Unit Level 1 Error Flag
25300 to 25307
FAL number output area.
25308
Low Battery Flag
25309
Cycle Time Error Flag
25310
I/O Verification Error Flag
25311
Rack-mounting Host Link Unit Level 0 Error Flag
25312
Remote I/O Error Flag
25411
Interrupt Input Unit Error Flag
25413
Interrupt Programming Error Flag
25414
Group-2 High-density I/O Unit Error Flag
25415
Special Unit Error Flag (Special I/O, PC Link, Host Link, Remote I/O Master, SYSMAC NET Link, or
SYSMAC Link Unit Error Flag)
25503
Instruction Execution Error (ER) Flag
26400 to 26403
RS-232C Port Error Code
26404
RS-232C Port Communications Error
26408 to 26411
Peripheral Port Error Code (except Peripheral Mode)
26412
Peripheral Port Communications Error Flag (except Peripheral Mode)
27011
UM Transfer Error Flag: SYSMAC NET data link active during data link table transfer.
27012
UM Transfer Error Flag: Not PROGRAM mode
27013
UM Transfer Error Flag: Read Only
27014
UM Transfer Error Flag: Insufficient capacity or no UM
27015
UM Transfer Error Flag: Board Checksum Error
27211
Memory Error Flag: PC Setup Checksum Error
27212
Memory Error Flag: UM or Ladder Checksum Error
27213
Memory Error Flag: Expansion Instruction Code Change Area Checksum Error
27214
Memory Error Flag: Memory Cassette Online Disconnection
27215
Memory Error Flag: Autoboot Error
27312
IOM Transfer Error Flag: Not PROGRAM mode
27313
IOM Transfer Error Flag: Read Only
27314
IOM Transfer Error Flag: Insufficient capacity
27315
IOM Transfer Error Flag: Checksum Error
27500
PC Setup Error (DM 6600 to DM 6614)
27501
PC Setup Error (DM 6615 to DM 6644)
27502
PC Setup Error (DM 6645 to DM 6655)
The following table lists the flags and other information provided in the SR and
AR areas that can be used in troubleshooting. Details are provided in 3-4 SR
Area and 3-5 AR Area.
Function
Section 10-5
397

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents