Press the Configuration button to open the Configuration
menu:
Setting
Meaning
Status
Interface active: Connection status of
the selected Ethernet interface
Name: Name of the interface you are
currently configuring
Plug connection: Number of the plug
connection of this interface on the logic
unit of the control
Profile
Here you can create or select a profile in
which all settings shown in this window are
stored. HEIDENHAIN provides two standard
profiles:
DHCP-LAN: Settings for the standard
TNC Ethernet interface, should work in a
standard company network
MachineNet: Settings for the second,
optional Ethernet interface; for
configuration of the machine network
Press the corresponding buttons to save,
load and delete profiles
IP address
Option Automatically procure IP
address: The TNC is to procure the IP
address from the DHCP server
Option Manually set IP address: Manually
define the IP address and subnet mask.
Input: Four numerical values separated
by periods, e.g.160.1.180.20 and
255.255.0.0
Domain Name
Option Automatically procure DNS: The
Server (DNS)
TNC is to automatically procure the IP
address of the domain name server
Option Manually configure the DNS:
Manually enter the IP addresses of the
servers and the domain name
Default
Option Automatically procure default
gateway
gateway: Die TNC soll den Default-
Gateway automatisch beziehen
Option Manually configure the default
gateway: Manually enter the IP addresses
of the default gateway
Apply the changes with the OK button, or discard them with the
Cancel button