9.11
Preassigned Q parameters
The Q parameters Q100 to Q199 are assigned values by the TNC.
The following types of information are assigned to Q parameters:
Values from the PLC
Tool and spindle data
Data on operating status
Results of measurements from touch probe cycles etc.
The TNC saves the values for the preassigned Q parameters Q108,
Q114 and Q115 to Q117 in the unit of measure used by the active
program.
Preassigned Q parameters (QS parameters) between
Q100 and Q199 (QS100 and QS199) must not be
used in NC programs as calculation parameters.
Otherwise you might receive undesired results.
Values from the PLC: Q100 to Q107
The TNC uses the parameters Q100 to Q107 to transfer values
from the PLC to an NC program.
Active tool radius: Q108
The active value of the tool radius is assigned to Q108. Q108 is
calculated from:
Tool radius R (tool table or G99 block)
Delta value DR from the tool table
Delta value DR from the T block
The TNC remembers the current tool radius even if
the power is interrupted.
Tool axis: Q109
The value of Q109 depends on the current tool axis:
Tool axis
No tool axis defined
X axis
Y axis
Z axis
U axis
V axis
W axis
HEIDENHAIN | TNC 620 | ISO Programming User's Manual | 9/2016
Preassigned Q parameters 9.11
Parameter value
Q109 = –1
Q109 = 0
Q109 = 1
Q109 = 2
Q109 = 6
Q109 = 7
Q109 = 8