With an operating error, e.g. pressing an impermissible key or
entering a value outside of a validity range, the TNC notifies you of
this with an information text in the header of the operating error.
The TNC deletes this information text with the next valid entry.
Save service files
If necessary, you can save the "Current status of the TNC," and
make it available to a service technician for evaluation. A group of
service files is saved (error and keystroke logs, as well as other
files that contain information about the current status of the
machine and the machining operation).
If you repeat the Save service files function with the same
file name, the previously saved group of service data files is
overwritten. To avoid this, use another file name when you repeat
the function.
Saving service files
Open the error window.
Press the LOG FILES soft key
Press the SAVE SERVICE FILES soft key: The TNC
opens a pop-up window in which you can enter a
file name or a complete path for the service file
Save the service files: Press the OK soft key
Calling the TNCguide help system
You can call the TNC's help system via soft key. Immediately the
help system shows you the same error explanation that you receive
by pressing the HELP soft key.
If your machine manufacturer also provides a help
system, the TNC shows an additional MACHINE
MANUFACTURER (OEM) soft key with which you
can call this separate help system. There you will
find further, more detailed information on the error
message concerned.
Call the help for HEIDENHAIN error messages
Call the help for HEIDENHAIN machine-specific
error messages, if available