HEIDENHAIN TNC 620 User Manual page 520

Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

14
Manual Operation and Setup
14.7 Using a 3-D touch probe (option 17)
Writing measured values from the touch probe
cycles to the preset table
Use this function if you want to save measured
values in the machine coordinate system (REF
coordinates). If you want to save measured values in
the workpiece coordinate system, press the ENTER
IN DATUM TABLE soft key.
Further Information:
the touch probe cycles to a datum table", page 519
With the ENTRY IN PRESET TABLE soft key, the TNC can write
the values measured during any probe cycle in the preset table.
The measured values are then stored referenced to the machine
coordinate system (REF coordinates). The preset table has the
name PRESET.PR, and is saved in the directory TNC:\table\.
Select any probe function
Enter the desired coordinates for the datum in the designated
input boxes (depends on the touch probe cycle being run)
Enter the preset number in the Number in table: input box
Press the ENTRY IN PRESET TABLE soft key. The TNC saves the
datum in the preset table under the entered number
Preset number is not available: The TNC saves the row only
after pressing the OK soft key (Create row in table?)
Preset number is protected: Press the OK soft key and the
active preset will be overwritten
Preset number is password-protected: Press the OK soft key,
enter the password and the active preset will be overwritten
If writing to the table row is not possible due to a
lock, the control displays a message. The probing is
not aborted, however.