In the part program, program D16 to activate the output:
N90 D16 P01 TNC:\MASK\MASK1.A/ TNC:\PROT1.TXT
The TNC then creates the file PROT1.TXT:
MEASURING LOG OF IMPELLER CENTER OF GRAVITY
DATE: July 15, 2015
TIME: 8:56:34 AM
NO. OF MEASURED VALUES : = 1
X1 = 149.360
Y1 = 25.509
Z1 = 37.000
If you output the same file more than once in the
program, the TNC appends all texts to the end of the
texts already output within the target file.
If you use D16 more than once in the program, the
TNC saves all texts in the file that you defined in the
D16 function. The file is not output until the TNC
reads the block, or you press the NC STOP key, or
you close the file with .
In the D16 block, program the format file and the log
file with their respective file type extensions
If you enter only the file name for the path of the
log file, the TNC saves the log file in the directory
in which the NC program with the D16 function is
located.
In machine parameters (no. 102202) and (no. 102203)
you can define a default path for outputting log files.
If you use D16 the file must not be UTF8-encoded.