Manual Operation and Setup
14.6 Datum setting without a 3-D touch probe
Using touch probe functions with mechanical
probes or measuring dials
If you do not have an electronic 3-D touch probe on your machine,
you can also use all the previously described manual touch probe
functions (exception: calibration function) with mechanical probes
or by simply touching the workpiece with the tool.
Further Information:
page 513
In place of the electronic signal generated automatically by a 3-D
touch probe during probing, you can manually initiate the trigger
signal for capturing the
Proceed as follows:
Select any touch probe function by soft key
Move the mechanical probe to the first position to
be captured by the TNC
Confirm the position: Press the ACTUAL-POSITION
CAPTURE soft key for the TNC to save the current
position
Move the mechanical probe to the next position to
be captured by the TNC
Confirm the position: Press the ACTUAL-POSITION
CAPTURE soft key for the TNC to save the current
position
If required, move to additional positions and
capture as described previously
Datum: In the menu window, enter the
coordinates of the new datum, confirm with the
SET DATUM soft key, or write the values to a table
Further Information:
from the touch probe cycles to a datum table",
page 519
Further Information:
from the touch probe cycles to the preset table",
page 520
Terminate the probing function: Press the END key
512
"Using a 3-D touch probe (option 17)",
probing position
by pressing a key.