HEIDENHAIN TNC 620 User Manual page 527

Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

Displaying calibration values
The TNC saves the effective length and effective radius of the
touch probe in the tool table. The TNC saves the touch probe
center offset to the touch probe table in the columns CAL_OF1
(principal axis) and CAL_OF2 (minor axis). You can display the
values on the screen by pressing the TCH PROBE TABLE soft key.
During calibration, the TNC automatically creates the
TCHPRMAN.html log file to which the calibration values are saved.
Please make sure the correct tool number is active
when you use the touch probe system. Regardless
of whether you want to use a touch probe cycle in
automatic mode or Manual operation mode.
For more information about the touch probe table,
refer to the User's Manual for Cycle Programming
HEIDENHAIN | TNC 620 | ISO Programming User's Manual | 9/2016
Calibrating 3-D touch probes (option 17) 14.8
14
527