Writing measured values from the touch probe
cycles to a datum table
Use this function to save measured values in the
workpiece coordinate system. If you want to save
measured values in the workpiece coordinate system
(REF coordinates), press the ENTRY IN PRESET
TABLE soft key.
Further Information:
from the touch probe cycles to the preset table",
page 520
With the ENTER IN DATUM TABLE soft key, the TNC can write the
values measured during any touch probe cycle as applicable to a
datum table:
Select any probe function
Enter the desired coordinates for the datum in the designated
input boxes (depends on the touch probe cycle being run)
Enter the datum number in the Number in table= input box
Press the ENTER IN DATUM TABLE soft key; the TNC saves the
datum in the specified datum table under the entered number
HEIDENHAIN | TNC 620 | ISO Programming User's Manual | 9/2016