The following functions allow you to include the following additional
information in the protocol log file:
Keyword
Function
CALL_PATH
Indicates the path for the NC program
where you will find the FN16 function.
Example: "Measuring program:
%S",CALL_PATH;
M_CLOSE
Closes the file to which you are writing with
FN16. Example: M_CLOSE;
M_APPEND
Upon renewed output, appends the log to
the existing log. Example: M_APPEND;
M_APPEND_MAX Upon renewed output, appends the log to
the existing log until the maximum specified
file size in kilobytes is exceeded. Example:
M_APPEND_MAX20;
M_TRUNCATE
Overwrites the log upon renewed output.
Example: M_TRUNCATE;
L_ENGLISH
Outputs text only for English conversational
language
L_GERMAN
Outputs text only for German conversational
language
L_CZECH
Outputs text only for Czech conversational
language
L_FRENCH
Outputs text only for French conversational
language
L_ITALIAN
Outputs text only for Italian conversational
language
L_SPANISH
Outputs text only for Spanish conversational
language
L_PORTUGUE
Outputs text only for Portuguese
conversational language
L_SWEDISH
Outputs text only for Swedish
conversational language
L_DANISH
Outputs text only for Danish conversational
language
L_FINNISH
Outputs text only for Finnish conversational
language
L_DUTCH
Outputs text only for Dutch conversational
language
L_POLISH
Outputs text only for Polish conversational
language
L_HUNGARIA
Outputs text only for Hungarian
conversational language
L_CHINESE
Outputs text only for Chinese
conversational language
L_CHINESE_TRAD Outputs text only for Chinese (traditional)
conversational language