9
Programming Q parameters
9.10
String parameters
Reading out machine parameters
Use the CFGREAD function to read out TNC machine parameters as
numerical values or as strings. The read values are always output in
metric units.
In order to read out a machine parameter, you must use the TNC's
configuration editor to determine the parameter name, parameter
object, and, if they have been assigned, the group name and index:
Icon
Type
Key
Entity
Attribute
Index
If you are in the configuration editor for the user
parameters, you can change the display of the
existing parameters. In the default setting, the
parameters are displayed with short, explanatory
texts. To display the actual system names of the
parameters, press the key for the screen layout key
and then the SHOW SYSTEM NAME soft key. Follow
the same procedure to return to the standard display.
Each time you want to interrogate a machine parameter with the
CFGREAD function, you must first define a QS parameter with
attribute, entity and key.
The following parameters are read in the CFGREAD function's
dialog:
KEY_QS: Group name (key) of the machine parameter
TAG_QS: Object name (entity) of the machine parameter
ATR_QS: Name (attribute) of the machine parameter
IDX: Index of the machine parameter
370
Meaning
Group name of the
machine parameter (if
available)
Parameter object (name
begins with "Cfg...")
Name of the machine
parameter
List index of a machine
parameter (if available)
Example
CH_NC
CfgGeoCycle
displaySpindleErr
[0]