PositionMonitoring tags (positioning axis/synchronous axis)

The tag structure <TO>.PositioningMonitoring.<tag name> contains the configuration for
position monitoring at the end of a positioning motion.
If the actual position value at the end of a positioning motion is reached within the tolerance
time and remains in the positioning window for the minimum dwell time, then
<TO>.StatusWord.X5 (Done) is set in the technology data block. This completes a Motion
Control job.
If the tolerance time is exceeded, then technology alarm 541 "Positioning monitoring" with
supplemental value 1: "Target area not reached within the positioning tolerance time" will be
indicated.
If the minimum dwell time is not met, then technology alarm 541 "Positioning monitoring"
with supplemental value 2: "Target area exited within the minimum dwell time" will be
indicated.
Tags
Legend (Page 332)
Tag
PositioningMonitoring.
ToleranceTime
MinDwellTime
Window
See also
Evaluating the technology data block (Page 173)
346
Data type
Values
STRUCT
LREAL
0.0 to 1.0E12
LREAL
0.0 to 1.0E12
LREAL
0.0 to 1.0E12
W
Description
DIR
Tolerance time
Maximum permitted duration from reaching velocity
setpoint zero, until entrance into the positioning
window.
DIR
Minimum dwell time in the positioning window:
DIR
Positioning window