Mc_Movevelocity; Mc_Movevelocity: Move Axes At Predefined Specified Velocity V1 - Siemens SIMATIC S7-1500 Function Manual

Update 3
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

This error is resolved by resetting the two inputs "Jog_F" and "Jog_B".
During the braking ramp, "Jog_F" is set at time
configured velocity. When the setpoint velocity 100.0 is reached, this is signaled via
"InVel" = TRUE.
11.2.4

MC_MoveVelocity

11.2.4.1

MC_MoveVelocity: Move axes at predefined specified velocity V1

Description
With the Motion Control instruction "MC_MoveVelocity", you can move an axis with a
constant velocity.
Dynamic behavior during movement is defined with the parameters "Velocity", "Jerk",
"Acceleration" and "Deceleration".
● Positioning axis:
● Speed axis:
Applies to
● Positioning axis
● Speed axis
Requirement
● The technology object has been configured correctly.
● The technology object is enabled.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
A velocity is specified in the "Velocity" parameter.
A speed is specified at the "Velocity" parameter.
11.2 S7-1500 Motion Control V1
. The axis is accelerated to the last
Instructions
297

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic s7-1500 motion control v13

Table of Contents