5.2

Changing a technology version

Before you can access all the benefits of a new technology version, you need to change the
technology version for existing projects.
Changing technology version to V2.0
To change the technology version to V2.0, follow these steps:
1. Replace the CPU V1.0...V1.5 in the project with a CPU V1.6.
2. Open the programming editor (e.g., by opening the OB1).
3. In the "Instructions" task card, open the technology version V2.0 in the
4. Save and compile the project.
5. Check the configuration of the technology objects.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
The technology objects and Motion Control instructions are highlighted in red after the
CPU is replaced.
"Technology > Motion Control > S7-1500 Motion Control" folder.
The version of the technology objects and Motion Control instructions is changed to V2.0
during compilation of the project.
Pay attention to any error information that is displayed during compilation. Deal with the
causes of the errors indicated.
Using versions
5.2 Changing a technology version