Parameters
The following table shows the parameters of the "MC_Reset" Motion Control instruction:
Parameter
Declaration
Axis
InOut
Execute
INPUT
Restart
INPUT
Done
OUTPUT
Busy
OUTPUT
Comman-
OUTPUT
dAborted
Error
OUTPUT
ErrorID
OUTPUT
Acknowledging technology alarms
To acknowledge technology alarms, follow these steps:
1. Check the requirements indicated above.
2. Set the parameter "Restart" = FALSE.
3. Start the acknowledgement of the error with a positive edge at parameter "Execute".
If the Done parameter shows the value TRUE, then the error was acknowledged.
Note
Acknowledging with "Restart" = FALSE
If only the technology alarms are to be acknowledged, set "Restart" = FALSE. The
technology object cannot be used during a restart.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Data type
Default value
TO_Axis
-
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
WORD
16#0000
Description
Technology object
Start of the job with a positive edge
TRUE
"Restart"
Reinitialization of the technology object and ac-
knowledgment of pending technology alarms. The
technology object is reinitialized with the config-
ured start values.
FALSE Acknowledgement of queued technology alarms.
TRUE
Error has been acknowledged.
Restart has been executed.
TRUE
The job is being executed.
TRUE
During execution the job was aborted by another
job.
TRUE
An error occurred during execution of the job. The
job is rejected. The cause of the error can be
found in the "ErrorID" parameter.
Error ID (Page 386) for parameter "Error"
Instructions
11.2 S7-1500 Motion Control V1
319