Technology alarm 110
Alarm reaction: No reaction
Restart: Not required
Alarm text
Configuration is being internally adapted.
Illegal value for Actor.MaxSpeed (Actor.MaxSpeed greater
than 2*Actor.Reference Speed; Actor.MaxSpeed is set to
2*Actor.Reference Speed.
The delay time to reach the tolerance window of positioning
monitoring (PositionMonitoring.ToleranceTime) is limited.
The emergency deceleration (Dynam-
icDefaults.EmergencyDeceleration) is too low and is set to the
minimum value possible.
A.4.3

Technology alarms 201-204

Technology alarm 201
Alarm reaction: Remove enable
Restart: Not required
Alarm text
Internal error.
Technology alarm 202
Alarm reaction: No reaction
Restart: Not required
Alarm text
Internal configuration error.
Technology alarm 203
Alarm reaction: Remove enable
Restart: Not required
Alarm text
Internal error. Please contact customer service.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Solution
Correct the reference value in the drive as well as in the
configuration of the technology object on
Actor.MaxSpeed/2. For the analog drive connection,
correct the reference value in the drive as well as in the
configuration of the technology object on
Actor.MaxSpeed/1.17.
Change the configuration datum.
Solution
Contact the hotline.
Solution
Contact the hotline.
Solution
Contact the hotline.