A.4.7

Technology alarm 601

Technology alarm 601
Alarm reaction: Stop with maximum dynamic values
Restart: Not required
Alarm text
The lead axis specified at the MC_GearIn.Master parameter is
not configured or not available.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Solution
Specify all master value interconnections for the configu-
ration required in operation for the synchronous axis
technology object.
If a restart is performed for a lead axis in synchronous
operation, the alarm is displayed and the following axis
is stopped with the maximum dynamic values.
Acknowledge the alarm after restarting the lead axis and
restart the synchronization.