Commissioning
9.3 Axis control panel
9.3.2

Using the axis control panel

Requirement
● The CPU must be in RUN mode.
● The project has been created and downloaded to the CPU.
● The technology object is disabled by your user program (MC_Power.Enable = FALSE).
● The axis control panel for the technology object is not used by another installation of the
TIA Portal (Team Engineering as of CPU V1.5).
Procedure
Proceed as follows to enable control the axis using the axis control panel:
1. Click "Activate" in the "Master control" area to assume master control over the technology
object and to set up an online connection to the CPU.
A warning message is displayed.
2. If necessary, adapt the sign-of-life monitoring and confirm with "OK".
3. In the "Axis" area, click the "Enable" button to enable the technology object.
4. In the drop-down list in the "Operation mode" area, select the desired function of the axis
control panel.
5. In the "Control" area, specify the parameter values for your job.
6. Click the "Start", "Forward" or "Backward" button to start the job.
7. Click the "Stop" button to stop the job.
8. Repeat steps 3 through 6 for additional jobs.
9. In the "Axis" area, click the "Disable" button to disable the technology object.
10. In the "Master control" area, click the "Deactivate" button to return master control to your
user program.
206
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC