Appendix
A.4 Technology alarms
No.
Response
531 Remove enable
531 Remove enable
533 Stop with maximum
dynamic values
534 Remove enable
541 Remove enable
550 Follow-up setpoints
601 Stop with maximum
dynamic values
See also
Technology alarms (Page 215)
370
Error bit
Warning bit
X9 (HWLimit)
-
X9 (HWLimit)
-
X8 (SWLimit)
-
X8 (SWLimit)
-
X12 (Postioning-
-
Fault)
X4 (DriveFault)
-
X14
-
(Synchronous
Error)
Restart
-
Positive HW limit switch reached.
Negative HW limit switch reached.
Incorrect traverse direction with ac-
tive hardware limit switch
X
Hardware limit switch polarity is re-
versed, axis cannot be freed
Both hardware limit switches are
active, axis cannot be freed
-
Software limit switch reached.
-
Software limit switch passed.
-
Positioning monitoring error.
-
The drive performs a autonomous
movement.
-
The lead axis specified at the
MC_GearIn.Master parameter is not
configured or not available.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Alarm text